Technical service

Techcon TS250/TS350 Glue Dispensing Machine User Manual

Release Date:2017-07-25

TechconTaikang TS250/TS350 Glue Dispensing Machine User Manual


TS250/TS350DispenserSafety NoteImportant matters:

1.Do not exceed the maximum rated power when operating this device/set up

2.Be sure to wear appropriate personal protective clothing

3.Only the following power adapter models can be used:PSA15R-240P(ZJ)orPW118RA2403B01ThePW118RA2403H01ThePW118RA2403M01ThePW118RA2403G01

4.Be careful to prevent corrosive or flammable liquids from flowing back into the equipment at the entrance. If corrosive or flammable liquids are used, an intake pipe filter must be installed on the dispensing machine(881-000-000)To prevent liquid from being sucked back into the equipment

5.Glue may be toxic and/Or hazardous substances. Please carefully read the "Material Safety Data Sheet" and safety regulationsmatters needing attention

6.If the piston is not used in conjunction with the syringe, an intake pipe filter must be installed on the receiver head(881-000-000)To prevent liquid from being sucked back into the equipment. Do not overfill the syringe and use itSide placement

7.Do not smoke or use open flames when dispensing flammable liquids

8.This device can only be used indoors
6.JPG

6.1 Manual/Glue dispensing cycle setting:

1. Press the 'Power' button(1)Open the device.

2. Press the 'Mode' button(2)Until it appears on the monitor“PURGERemove the glue.

3. By rotating the pressure adjustment knob(5)Until the required dispensing pressure is displayed

4. After filling the syringe or using pre packaged adhesive, attach the syringe to the receiver head assembly. Ensure that the syringe is fixed in the appropriate position.

5. Connect the insertion end of the receiver head assembly to one of the pneumatic dispensing outlets(6).

6. If vacuum suction is required, rotate the vacuum pressure knob counterclockwise(7)The required vacuum pressure can be displayed.

7. Press the foot switch to activate the dispensing cycle. (Manually at this moment)/The glue dispensing mode is activated


6.2 Automatic dispensing cycle setting

6.2.1Program selection

1.Press the settings button(3)Until“P:”Start flashing

2.Rotate program selection button(8)Select the required program

6.2.2time setting

1.Press the mode button(2)Select the desired time mode

2.Press and release the settings button(3)Until time(:)Start flashing.

3.Rotate the time knob(8)Select the required dispensing time

4.Press the foot pedal switch to start the dispensing cycle


6.3 Training mode setting

In training mode, as long as the foot switch is pressed down, the device will accumulate time. This helps determine the necessary dispensing time when the dispensing output is unknown.

1. Press the mode button(2)Select training mode.

2. Press and release the settings button(3)Until the dispensing time= 0.000S

3. Press the 'foot pedal' switch. During this operation, the dispensing time will accumulate continuously.

4. When the dispensing reaches the appropriate amount, release the "foot pedal" switch.

5. Press and hold the 'Settings' button(3)continued 2 Save data in seconds.

6. Press the 'Mode' button(2)Convert to“TIMED(Continuous) mode.

7. At this moment, the dispensing machine is set to repeat this cycle.


6.4 Continuous dispensing program settings:

TS350/TS355Can store up to 10 Apply adhesive independently or continuously.

1. according to 6.2 Select the automatic dispensing time in the required program for the steps.

2. Simultaneously press the settings button(3)And the power button(1)Start a continuous dispensing program.

3. Press and hold the settings button(3)Maintaining TimeSeconds, can save the program for continuous dispensing.

The dispensing machine now saves the continuous dispensing program.

4. Press the mode button(2)Exit the continuous dispensing program.


6.5 Cyclic counter

The cycle counter records the number of activated automatic dispensing cycles. The maximum number of cycles that can be recorded is65,535Article. This number is displayed on the LCD monitor(LCD)The bottom right corner. In order to clear the meterNumber, you can hold down the settings button at the same time(3)And mode button(2)Until the counter is“0.


6.6 Adjust the dispensing pressure and vacuum pressure display

1. Press and release the settings button(3)until(:)Flashing on dispensing pressure and vacuum pressure

2. Rotate the time knob(8)Select the desired display value


Troubleshooting of TS250/TS350 Glue Dispensing Machine

fault

Possible reasons

Troubleshooting methods

LCDNot lit up

? Not powered on

Check the power cord connection
? Turn on the power

The system cannot start

? The 'foot pedal' switch is not connected or the plug is not inserted correctly
There is an issue with the foot switch
The internal wiring of the device is damaged or the connection is not secure
There is a problem with the solenoid coil
?PCThere is a problem with the board

Check the connection of the foot switch
? Repair or replace the foot switch
Unplug the power cord and disconnect the air source. Remove the cover and check for damaged wires or loose connections
? Replace the solenoid coil
? ReplacePCplate

The system cannot boost the pressure

? Insufficient air pressure
The air hose is not connected
There is a problem with the regulator

? Increase the pressure of the gas source
? Check the connection
? Replace the regulator

The system cannot be evacuated

The vacuum setting is too low
There is a problem with the solenoid coil
There is an issue with the vacuum Venturi tube
There is a problem with the vacuum needle valve

? Increase the vacuum setting
Replace the solenoid valve
? Replace the Venturi tube
Replace the needle valve

Inconsistent glue dispensing

There are bubbles in the adhesive
The dispensing time is too short
At the beginning, the dispensing needle is blocked

? Reduce the vacuum setting
? Extend the dispensing time
? Replace the needle


TS250/TS350 Glue Dispensing Machinemaintain

This dispensing machine has become increasingly sophisticated in both design and manufacturing, greatly reducing maintenance requirements. To ensure trouble free operation, please follow the following recommendations:

1. Ensure that the gas source is clean and dry.

2. Avoid reversing or placing the syringe flat, as this may cause liquid to pass through the gas pipeline and enter the internal components.

3. Avoid connecting the equipment to gases or saturated solutions with excessive humidity.

4. Avoid exceeding the pressure of the connected gas sourceTS350The prescribed100 psi6.9 Ba) andTS355The prescribed15 psi1.03 Ba).

5. Only use pentanol to clean the outer surface of the mainframe.

6. Wipe the LCD monitor with only soft fabric(LCD).


展開
av在线观看网址| 国产精久久一区二区三区| 欧美性受xxxx88喷潮| 好吊色欧美一区二区三区视频| 女人被弄到高潮的免费视频| 校花张开腿疯狂娇吟k视频| 亚洲精品97久久中文字幕无码 | 一本久道中文无码字幕AV| 玩弄人妻少妇500系列视频| 欧美疯狂做爰3xxx高清| 国产精品久久久| 久久AV无码专区亚洲AV桃花岛| 熟女丰满老熟女熟妇| 孕妇滴着奶水做着爱a| 最近韩国高清完整版播放电影| 国内少妇毛片视频| 年轻又漂亮的后妈2| 亚洲欧美妆和亚洲妆的区别| 色欲精品人妻AV一区二区三区| 亚洲综合激情另类小说区| 久久久受WWW免费人成| bgmbgmbgm老太太视频| 欧美a级suv大全| 亚洲国产精华液2020| 久久精品国产亚洲AV日韩| 亚洲精品乱码久久久久久蜜桃不卡 | 国产精品久久无码一区二区三区网| 最穷的山村妇女做爰| 被群cao的合不拢腿h纯肉视频| 国产老头老太作爱视频| 欧美又粗又大又黄的片| 中文字幕AV人妻一本二本| 久久久久久精品免费无码| 国产精品妇女一二三区| 铁矿石期货实时行情| 成人免费电影网站| 亚洲精品中文字幕| 小雪被老汉各种姿势玩弄| 特黄特色大片免费播放器图片| 日韩人妻精品无码一区二区三区| 久久久WWW成人免费毛片|